Product: 12mm ID to 4mm ID x 40mm Length
Heat Shrink – RECP Adhesive Lined End Caps
Applications:
Provides sealing and protection of cable ends for power cables to 1kV and telecommunications cables.
General:
- Resistance to chemical, fuel oil, insulation oil, copper corrosion and fungus
- Hot melt adhesive for effective water and environmental sealing
- High tensile strength
- UV stabilised
RECP Heat Shrink End Cap Circular Dimensions | |||||
Part Number |
As Supplied | After Recovery (mm) | |||
Inside Ø | Inside Ø | Wall | |||
RECP8-2 | 8mm | ≤ 2mm | 1.5 | ||
RECP12-4 | 12mm | ≤ 4mm | 1.8 | ||
RECP14-4 | 14mm | ≤ 4mm | 2.0 | ||
RECP25-8 | 25mm | ≤ 8mm | 2.2 | ||
RECP40-15 | 40mm | ≤ 15mm | 2.2 | ||
RECP55-25 | 55mm | ≤ 25mm | 2.7 | ||
RECP75-35 | 75mm | ≤ 35mm | 2.9 | ||
RECP100-45 | 100mm | ≤ 45mm | 3.0 | ||
RECP130-63 | 130mm | ≤ 63mm | 3.0 | ||
RECP158-60 | 158mm | ≤ 60mm | 3.0 |
(RECP12-4)
RECP End Caps | Testing Method | Requirement / Result | |
Tensile Strength | ASTM-D-638 | 14 N/mm² | |
Tensile Strength after Aging | BS 6910-1 | 11N/mm² | |
Elongation at Break | ASTM-D-638 | 350 % | |
Water Absorption | |||
ASTM-D-570 | <0.15% Max | ||
Hardness | ASTM-D-2240 | 45 +/-10 Shore D | |
Accelerated Aging | ASTM-D-2671 | 120°C 500hrs | |
Continuous Operating Temperature | IEC 216 | - 40°C to +100°C | |
Heat Shock at 200°C for 4hrs | ASTM-D-2671 | No dripping, cracking or flowing | |
Fungus Resistance | ISO 846 Method A | Rating 1 | |
Copper Corrosion | ASTM-D-2671 B | Good | |
Dielectric Strength | ASTM-D-2671 B | >12kV/mm | |
Dielectric Constant | ASTM-D-150 | 5.0 Max | |
Volume Resistance | ASTM-D-257 | 1014Ohm/cm |
SKU | RECP12-4 |
Brand | Radiform |
Be The First To Review This Product!
Help other Red2go Pty Ltd users shop smarter by writing reviews for products you have purchased.